Human ATP Binding Cassette Transporter C5 (ABCC5) ELISA Kit

Human ATP Binding Cassette Transporter C5 (ABCC5) ELISA Kit ABCC5 DL-ABCC5-Hu ABC-C5 ABC33 MOAT-C MOATC MRP5 SMRP pABC11 Multidrug Resistance-Associated Protein 5 Multi-specific organic anion transporter C
0
Human ATP Binding Cassette Transporter C5 (ABCC5) ELISA Kit ABCC5 DL-ABCC5-Hu ABC-C5 ABC33 MOAT-C MOATC MRP5 SMRP pABC11 Multidrug Resistance-Associated Protein 5 Multi-specific organic anion transporter C code image

two product lines: Traditional ELISA Kit and Ready-to-Use ELISA Kit.

Traditional ELISA Kit Ready-to-Use ELISA KIT
Product name: Human ATP Binding Cassette Transporter C5 (ABCC5) ELISA Kit
Method: Competition
Synonyms:

ABC-C5; ABC33; MOAT-C; MOATC; MRP5; SMRP; pABC11; Multidrug Resistance-Associated Protein 5; Multi-specific organic anion transporter C

Detection range: 0.156-10ng/mL
Target Protein: ABCC5
Size: 96T/48T
Quality guarantee period: for 12 months, 16 months
Catalog number: DL-ABCC5-Hu (traditional) (ready-to-use)
Assay length 1-2.5Hours 1-2.5Hours
Advantages:
  • Competitive price.
  • High sensitivity.
  • High stability.
  • 12 months shelf life.
  • Pre-diluted Detection Reagent A and B
  • Reduction in the number of steps when conducting the test
  • All the reagents can be stored at -20℃
  • Faster reaction compare to other brands
  • 16 months shelf life
Instruction Manual DL-ABCC5-Hu.pdf DL-ABCC5-Hu.pdf
Human ATP Binding Cassette Transporter C5 (ABCC5) ELISA Kit elisa kit elisa kits
1. Overview

Other names:ABC-C5; ABC33; MOAT-C; MOATC; MRP5; SMRP; pABC11; Multidrug Resistance-Associated Protein 5; Multi-specific organic anion transporter C

Function: Acts as a multispecific organic anion pump which can transport nucleotide analogs.

Sequence
MKDIDIGKEY  IIPSPGYRSV  RERTSTSGTH  RDREDSKFRR  TRPLECQDAL  
ETAARAEGLS  LDASMHSQLR  ILDEEHPKGK  YHHGLSALKP  IRTTSKHQHP  
VDNAGLFSCM  TFSWLSSLAR  VAHKKGELSM  EDVWSLSKHE  SSDVNCRRLE  
RLWQEELNEV  GPDAASLRRV  VWIFCRTRLI  LSIVCLMITQ  LAGFSGPAFM 
VKHLLEYTQA  TESNLQYSLL  LVLGLLLTEI  VRSWSLALTW  ALNYRTGVRL  
RGAILTMAFK  KILKLKNIKE  KSLGELINIC  SNDGQRMFEA  AAVGSLLAGG  
PVVAILGMIY  NVIILGPTGF  LGSAVFILFY  PAMMFASRLT  AYFRRKCVAA  
TDERVQKMNE  VLTYIKFIKM  YAWVKAFSQS  VQKIREEERR  ILEKAGYFQS  
ITVGVAPIVV  VIASVVTFSV  HMTLGFDLTA  AQAFTVVTVF  NSMTFALKVT  
PFSVKSLSEA  SVAVDRFKSL  FLMEEVHMIK  NKPASPHIKI  EMKNATLAWD  
SSHSSIQNSP  KLTPKMKKDK  RASRGKKEKV  RQLQRTEHQA  VLAEQKGHLL  
LDSDERPSPE  EEEGKHIHLG  HLRLQRTLHS  IDLEIQEGKL  VGICGSVGSG  
KTSLISAILG  QMTLLEGSIA  ISGTFAYVAQ  QAWILNATLR  DNILFGKEYD  
EERYNSVLNS  CCLRPDLAIL  PSSDLTEIGE  RGANLSGGQR  QRISLARALY  
SDRSIYILDD  PLSALDAHVG  NHIFNSAIRK  HLKSKTVLFV  THQLQYLVDC  
DEVIFMKEGC  ITERGTHEEL  MNLNGDYATI  FNNLLLGETP  PVEINSKKET  
SGSQKKSQDK  GPKTGSVKKE  KAVKPEEGQL  VQLEEKGQGS  VPWSVYGVYI  
QAAGGPLAFL  VIMALFMLNV  GSTAFSTWWL  SYWIKQGSGN  TTVTRGNETS 
VSDSMKDNPH  MQYYASIYAL  SMAVMLILKA  IRGVVFVKGT  LRASSRLHDE  
LFRRILRSPM  KFFDTTPTGR  ILNRFSKDMD  EVDVRLPFQA  EMFIQNVILV  
FFCVGMIAGV  FPWFLVAVGP  LVILFSVLHI  VSRVLIRELK  RLDNITQSPF  
LSHITSSIQG  LATIHAYNKG  QEFLHRYQEL  LDDNQAPFFL  FTCAMRWLAV  
RLDLISIALI  TTTGLMIVLM  HGQIPPAYAG  LAISYAVQLT  GLFQFTVRLA  
SETEARFTSV  ERINHYIKTL  SLEAPARIKN  KAPSPDWPQE  GEVTFENAEM  
RYRENLPLVL  KKVSFTIKPK  EKIGIVGRTG  SGKSSLGMAL  FRLVELSGGC  
IKIDGVRISD  IGLADLRSKL  SIIPQEPVLF  SGTVRSNLDP  FNQYTEDQIW  
DALERTHMKE  CIAQLPLKLE  SEVMENGDNF  SVGERQLLCI  ARALLRHCKI  
LILDEATAAM  DTETDLLIQE  TIREAFADCT  MLTIAHRLHT  VLGSDRIMVL  
AQGQVVEFDT  PSVLLSNDSS  RFYAMFAAAE  NKVAVKG
 
2. Features
 
INTENDED USE
The kit is a sandwich enzyme immunoassay for the in vitro quantitative measurement of ABCC5 in human tissue homogenates, cell lysates and other biological fluids.

DETECTION RANGE
0.156-10ng/mL. The standard curve concentrations used for the ELISA’s were 10ng/mL, 5ng/mL, 2.5ng/mL, 1.25ng/mL, 0.625ng/mL, 0.312ng/mL, 0.156ng/mL.
 
SENSITIVITY
The minimum detectable dose of ABCC5 is typically less than 0.051ng/mL.
The sensitivity of this assay, or Lower Limit of Detection (LLD) was defined as the lowest protein concentration that could be differentiated from zero. It was determined by adding two standard deviations to the mean optical density value of twenty zero standard replicates and calculating the corresponding concentration.
 
SPECIFICITY
This assay has high sensitivity and excellent specificity for detection of ABCC5.
No significant cross-reactivity or interference between ABCC5 and analogues was observed.
Note: Limited by current skills and knowledge, it is impossible to perform all possible cross-reactivity detection tests between ABCC5 and all analogues, therefore, cross reactivity may still exist.
 
IMPORTANT NOTES
1. Limited by the current conditions and scientific technology, it is impossible to conduct comprehensive identification and analysis tests on the raw materials provided by suppliers. As a result, it is possible there are some qualitative and/or technical risks.
2. The final experimental results will be closely related to the validity of the products, operation skills of the end users and the experimental environments. Please make sure that sufficient samples are available to obtain accurate results.
3. Kits from different batches may be a little different in detection range, sensitivity and color developing time. Please perform the experiment exactly according to the instruction manual included in your kit. Electronic ones on our website are for reference only.
4. Do not mix or substitute reagents from one kit lot to another. Use only the reagents supplied by manufacturer.
5. Protect all reagents from strong light during storage and incubation. All bottle caps of reagents should be closed tightly to prevent evaporation of liquids and contamination by microorganisms.
6. There may be a foggy substance in the wells when the plate is opened at the first time. It will not have any effect on the final assay results. Do not remove microtiter plate from the storage bag until needed.
7. Incorrect procedures during reagent preparation and loading, as well as incorrect parameter setting for the plate reader may lead to incorrect results. A microplate plate reader with a bandwidth of 10nm or less and an optical density range of 0-3 O.D. or greater at 450 ± 10nm wavelength is acceptable for use in absorbance measurement. Please read the instruction carefully and adjust the instrument prior to the experiment.
8. Even the same experimenter may get different results from two separate experiments. In order to get better reproducible results, the operation of every step in the assay should be controlled. Furthermore, a preliminary experiment before the general assay for each batch is recommended.
9. Each kit has undergone several rigorous quality control tests. However, results from end users might be inconsistent with our in-house data due to some unexpected transportation conditions or different lab equipment. Intra-assay variance among kits from different batches could arise from the above factors as well.
10. Kits from different manufacturers with the same item might produce different results, since we have not compared our products with other manufacturers.
11. The standard of the kit and immunogen used for antibody preparation are commonly recombinant proteins. Different expressed sequence, expression systems, purification methods might be used in recombinant protein preparation. Besides, there might exist differences on the screening technique of antibody and antibody pairs in our kit. Thus we can not guarantee the kit could detect recombinant protein from other companies. So, it is not recommended to use the kit for the detection of recombinant protein.
12. Validity period: 12 months.
13. The instruction manual also works with the 48T kit, but all reagents in the 48T kit are reduced by half.
 
You can reference link of the kit as following
https://www.dldevelop.com/uploadfile/data/DL-ABCC5-Hu.pdf
Introduction
Item Standard Test
Description

The kit is a sandwich enzyme immunoassay for the in vitro quantitative measurement of ABCC5 in human tissue homogenates, cell lysates or other biological fluids.

Conform
IdentificationColorimetricPositive
Composition Traditional ELISA Kit Ready-to-Use ELISA KITConform
Pre-coated, ready to use 96-well strip plate 1Pre-coated, ready to use 96-well strip plate 1
Plate sealer for 96 wells 2Plate sealer for 96 wells 2
Standard 2 Standard 2
Diluents buffer 1×45mLStandard Diluent 1×20mL
Detection Reagent A 1×120μLDetection Solution A 1×12mL
Detection Reagent B 1×120μLDetection Solution B 1×12mL
TMB Substrate 1×9mLTMB Substrate 1×9mL
Stop Solution 1×6mLStop Solution 1×6mL
Wash Buffer (30 × concentrate) 1×20mLWash Buffer (30 × concentrate) 1×20mL
Instruction manual 1 Instruction manual 1

Test principle

This assay employs the competitive inhibition enzyme immunoassay technique. A monoclonal antibody specific to the index has been pre-coated onto a microplate. A competitive inhibition reaction is launched between biotin labeled the index and unlabeled the index (Standards or samples) with the pre-coated antibody specific to the index. After incubation the unbound conjugate is washed off. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. The amount of bound HRP conjugate is reverse proportional to the concentration of the index in the sample. After addition of the substrate solution, the intensity of color developed is reverse proportional to the concentration of the index in the sample.

Recovery

Matrices listed below were spiked with certain level of recombinant ABCC5 and the recovery rates were calculated by comparing the measured value to the expected amount of the index in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 81-93 86
EDTA plasma(n=5) 80-97 88
heparin plasma(n=5) 90-101 95

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of the index and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 82-96% 83-98% 81-99% 93-101%
EDTA plasma(n=5) 88-101% 86-95% 90-102% 80-93%
heparin plasma(n=5) 80-91% 82-90% 95-104% 79-95%

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level the index were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level the index were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
 

Stability

The stability of ELISA kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
Note:
To minimize unnecessary influences on the performance, operation procedures and lab conditions, especially room temperature, air humidity, and incubator temperatures should be strictly regulated. It is also strongly suggested that the whole assay is performed by the same experimenter from the beginning to the end.


Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 50µL standard or sample to each well.
    And then add 50µL prepared Detection Reagent A immediately.
    Shake and mix. Incubate 1 hour at 37℃;
3. Aspirate and wash 3 times;
4. Add 100µL prepared Detection Reagent B. Incubate 1 hour at 37℃;
5. Aspirate and wash 5 times;
6. Add 90µL Substrate Solution. Incubate 15-25 minutes at 37℃;
7. Add 50µL Stop Solution. Read at 450 nm immediately.