Human Roundabout Homolog 4 (ROBO4) ELISA Kit
two product lines: Traditional ELISA Kit and Ready-to-Use ELISA Kit.
Other names:Magic roundabout
Function: Receptor for Slit proteins, at least for SLIT2, and seems to be involved in angiogenesis and vascular patterning. May mediate the inhibition of primary endothelial cell migration by Slit proteins.
Sequence:
10 20 30 40 50 MGSGGDSLLG GRGSLPLLLL LIMGGMAQDS PPQILVHPQD QLFQGPGPAR 60 70 80 90 100 MSCQASGQPP PTIRWLLNGQ PLSMVPPDPH HLLPDGTLLL LQPPARGHAH 110 120 130 140 150 DGQALSTDLG VYTCEASNRL GTAVSRGARL SVAVLREDFQ IQPRDMVAVV 160 170 180 190 200 GEQFTLECGP PWGHPEPTVS WWKDGKPLAL QPGRHTVSGG SLLMARAEKS 210 220 230 240 250 DEGTYMCVAT NSAGHRESRA ARVSIQEPQD YTEPVELLAV RIQLENVTLL 260 270 280 290 300 NPDPAEGPKP RPAVWLSWKV SGPAAPAQSY TALFRTQTAP GGQGAPWAEE 310 320 330 340 350 LLAGWQSAEL GGLHWGQDYE FKVRPSSGRA RGPDSNVLLL RLPEKVPSAP 360 370 380 390 400 PQEVTLKPGN GTVFVSWVPP PAENHNGIIR GYQVWSLGNT SLPPANWTVV 410 420 430 440 450 GEQTQLEIAT HMPGSYCVQV AAVTGAGAGE PSRPVCLLLE QAMERATQEP 460 470 480 490 500 SEHGPWTLEQ LRATLKRPEV IATCGVALWL LLLGTAVCIH RRRRARVHLG 510 520 530 540 550 PGLYRYTSED AILKHRMDHS DSQWLADTWR STSGSRDLSS SSSLSSRLGA 560 570 580 590 600 DARDPLDCRR SLLSWDSRSP GVPLLPDTST FYGSLIAELP SSTPARPSPQ 610 620 630 640 650 VPAVRRLPPQ LAQLSSPCSS SDSLCSRRGL SSPRLSLAPA EAWKAKKKQE 660 670 680 690 700 LQHANSSPLL RGSHSLELRA CELGNRGSKN LSQSPGAVPQ ALVAWRALGP 710 720 730 740 750 KLLSSSNELV TRHLPPAPLF PHETPPTQSQ QTQPPVAPQA PSSILLPAAP 760 770 780 790 800 IPILSPCSPP SPQASSLSGP SPASSRLSSS SLSSLGEDQD SVLTPEEVAL 810 820 830 840 850 CLELSEGEET PRNSVSPMPR APSPPTTYGY ISVPTASEFT DMGRTGGGVG 860 870 880 890 900 PKGGVLLCPP RPCLTPTPSE GSLANGWGSA SEDNAASARA SLVSSSDGSF 910 920 930 940 950 LADAHFARAL AVAVDSFGFG LEPREADCVF IDASSPPSPR DEIFLTPNLS 960 970 980 990 1000 LPLWEWRPDW LEDMEVSHTQ RLGRGMPPWP PDSQISSQRS QLHCRMPKAG ASPVDYS
INTENDED USE
The kit is a sandwich enzyme immunoassay for the in vitro quantitative measurement of ROBO4 in human serum, plasma, tissue homogenates or other biological fluids.
DETECTION RANGE
0.156-10ng/mL. The standard curve concentrations used for the ELISA’s were 10ng/mL, 5ng/mL, 2.5ng/mL, 1.25ng/mL, 0.625ng/mL, 0.312ng/mL, 0.156ng/mL.
SENSITIVITY
The minimum detectable dose of ROBO4 is typically less than 0.050g/mL.
The sensitivity of this assay, or Lower Limit of Detection (LLD) was defined as the lowest protein concentration that could be differentiated from zero. It was determined by adding two standard deviations to the mean optical density value of twenty zero standard replicates and calculating the corresponding concentration.
SPECIFICITY
This assay has high sensitivity and excellent specificity for detection of ROBO4.
No significant cross-reactivity or interference between ROBO4 and analogues was observed.
You can reference link of the kit as following
https://dldevelop.com/Research-reagent/dl-robo4-hu.html
https://www.dldevelop.com/uploadfile/data/DL-ROBO4-Hu.pdf
Introduction
Item | Standard | Test | |
Description |
The kit is a sandwich enzyme immunoassay for the in vitro quantitative measurement of the index in serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids. |
Conform | |
Identification | Colorimetric | Positive | |
Composition | Traditional ELISA Kit | Ready-to-Use ELISA KIT | Conform |
Pre-coated, ready to use 96-well strip plate 1 | Pre-coated, ready to use 96-well strip plate 1 | ||
Plate sealer for 96 wells 2 | Plate sealer for 96 wells 2 | ||
Standard 2 | Standard 2 | ||
Diluents buffer 1×45mL | Standard Diluent 1×20mL | ||
Detection Reagent A 1×120μL | Detection Solution A 1×12mL | ||
Detection Reagent B 1×120μL | Detection Solution B 1×12mL | ||
TMB Substrate 1×9mL | TMB Substrate 1×9mL | ||
Stop Solution 1×6mL | Stop Solution 1×6mL | ||
Wash Buffer (30 × concentrate) 1×20mL | Wash Buffer (30 × concentrate) 1×20mL | ||
Instruction manual 1 | Instruction manual 1 |
Test principle
The microtiter plate provided in this kit has been pre-coated with an antibody specific to the index. Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody preparation specific to the index. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain the index, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of the index in the samples is then determined by comparing the O.D. of the samples to the standard curve.
Recovery
Matrices listed below were spiked with certain level of recombinant ROBO4 and the recovery rates were calculated by comparing the measured value to the expected amount of the index in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 81-93 | 86 |
EDTA plasma(n=5) | 80-97 | 88 |
heparin plasma(n=5) | 90-101 | 95 |
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of the index and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 82-96% | 83-98% | 81-99% | 93-101% |
EDTA plasma(n=5) | 88-101% | 86-95% | 90-102% | 80-93% |
heparin plasma(n=5) | 80-91% | 82-90% | 95-104% | 79-95% |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level the index were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level the index were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Stability
The stability of ELISA kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage conditions.
Note:
To minimize unnecessary influences on the performance, operation procedures and lab conditions, especially room temperature, air humidity and incubator temperatures should be strictly regulated. It is also strongly suggested that the whole assay is performed by the same experimenter from the beginning to the end.
Assay procedure summary
1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 2 hours at 37℃;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37℃;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 1 hour at 37℃;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 15-25 minutes at 37℃;
8. Add 50µL Stop Solution. Read at 450nm immediately.